Error Warning Controls in StatiCAD Project Error Checks Report
When the following controls cannot be satisfied in the project, a warning is displayed on the Project Error Checks report page. For cases where no warning is shown, the relevant reports indicate whether the verifications are met.
The program issues a warning in the Project Error Checks report when the following conditions according to TBDY2018 are not met:
General Checks:
- Effective Relative Story Drift Limit exceeded
- B1 Strength Irregularity Between Adjacent Stories (Weak Story) found
- B2 Irregularity check
- B3 Vertical Element Discontinuity
- Incorrect ductility level selection
- TBDY2018 Articles 4.3.2.4, 4.3.4.5, 4.3.4.6 Shear wall overturning moment condition
Columns:
- Column Slenderness Lower Limit
- TBDY2018 Art. 7.3.1.1: Minimum cross-section dimension of rectangular columns less than 300 mm
- TBDY2018 Art. 7.3.1.1: Circular column diameter less than 350 mm
- TBDY2018 Art. 7.3.1.2: Ac ≥ Ndm / (0.40 fck) condition
- TS500-2000 F7.7: Nd ≤ 0.9 fcd Ac condition
- αx < 0 value (column number exceeding the limit value)
- TS500 Slenderness Limit when Total Nd > 0.45 × Total Nk
Shear Walls:
- Shear Wall Axial Force Limit exceeded
- Per Article 7.6.1.2: Shear Wall Thickness Condition
- Shear wall length to thickness ratio less than 6